Overwiew

The Integriti 8 Zone LAN Expander Module connects directly to the Integriti or Inception RS-485 LAN and provides an additional 8 Zone Inputs, 2 Auxiliary Outputs, and 2 Siren drivers*. Up to 99 Zone Expander Modules can be connected to the RS-485 LAN or via IP LAN if connected with CLOE modules (Part 995093).

The 8 Zone LAN Expander Module is compatible with the following System Controllers:

  • Integriti ISC & IAC Controllers
  • Inception Controllers
  • Infiniti ISC & IAC Controllers
  • Infiniti Class 5 Controllers

The 8 Zone LAN Expander Module also offers a UniBus in-cabinet expansion interface allowing further expansion of Zone inputs and Auxiliary outputs using plug on UniBus expansion devices fitted within the same tamper protected enclosure. Up to 32 Zone Inputs or 32 Auxiliary Outputs can be connected to the Module. (32 Zones and 26 Auxiliaries or 24 Zones and 32 Auxiliaries at the same time)

The power supply requirement is 11 to 14VDC and a range of Integriti plug on external 2Amp, 3Amp or 8Amp switch mode power supplies are available. Integriti external power supplies are fully monitored via the 8 Zone Expander Module.

Expansion Capabilities

The 8 Zone LAN Expander Module features 8 Zone Inputs and 2 Auxiliary relay outputs on-board and is expandable via a UniBus in-cabinet expansion interface allowing further expansion of Zones and Auxiliaries using plug on UniBus expansion devices fitted within the same tamper protected enclosure. Up to 32 Zone Inputs or 32 Auxiliary Outputs can be connected to the Module.

  • Zone Inputs – Expandable to 32 via UniBus*
  • Auxiliary Outputs (Relays) – Expandable to 32 via UniBus*

* Limited to 32 Zones and 26 Auxiliaries or 24 Zones and 32 Auxiliaries at the same time

UniBus In-Cabinet Expansion

UniBus Devices are designed for installation within the same tamper protected enclosure as the UniBus host module. A UniBus host can interface a maximum of six UniBus devices in any combination, provided they are all within the intended functionality of the host module.

UniBus is an innovative in-cabinet bus that allows the connection of Expansion devices, Communications devices, and Door & Reader expansion devices on a common Plug & Play bus. UniBus is built on the highly reliable CANBus technology and replaces the need for ribbon cables and specialized connectors.

Features:

  • RS-485 LAN connectivity
  • UniBus In-Cabinet Expansion Interface
  • 8 Zone Inputs – Multistate or Analogue
  • 2 Auxiliary Output Relays
  • External Integriti power supply connection
  • Three options for power supply size 2Amp, 3 Amp & 8 Amp
  • Six enclosure size options
  • Dedicated Tamper Input
  • 4 Terminals supplying 13.75Vdc nominal Detector Power
  • Remote firmware upgrade over-the-wire
  • On board diagnostic LEDs to assist with commissioning and troubleshooting
  • Small PCB size 200 x 95mm

Specifications
Physical
Enclosure Options:
Xtra Small – 995200XS Series – 252(L) x 263(W) x 85(D) (mm) (No PSU)
Small – 995200PEI Series – 252(L) x 358(W) x 85(D) (mm) (with 2Amp PSU)
Medium – 995201PEI Series – 460(L) x 358(W) x 85(D) (mm) (with 3Amp SMART PSU)
XLarge – 995203PEI Series – 702(L) x 358(W) x 85(D) (mm) (with 3Amp SMART PSU)
XLarge – 995203PE8 Series – 702(L) x 358(W) x 85(D) (mm) (with 8Amp SMART PSU)
WideBody – 995204PE8 Series – 580(L) x 510(W) x 95(D) (mm) (with 8Amp SMART PSU)
Rack Mount – 995220PEI Series – 2RU 680(L) x 420(W) x 85(D) (mm) (with 3Amp SMART PSU)
PCB Size Code: Integriti “B” size
PCB Dimensions: 200(L) x 94(W) x 45(D) (mm)
Weight: 300g (For PCB & accessories Only)
Installation Environment: 0ºC – 70ºC @15% – 90% Relative humidity (non-condensing)
Electrical (For PCB Only)
Power Supply Input: 11V to 14VDC
Current Consumption: 60mA standby. 100mA with both Aux relays on
NOTE: Current consumption does not include the current required by detectors or other external devices such as buzzers, lamps or any device attached to the DET+, LAN+ and UniBus connections
Contact Ratings
Aux Relays: 2 Amps @ 30VDC
Connections
Zone Inputs: 8 x Multistate Zone Inputs
Aux Outputs: 2 x Relay Output NO|COM|NC
Cabinet Tamper: 2 pin connection for cabinet tamper switch
UniBus Port: 1 x UniBus Host expansion port
RS-485 LAN: 1, Includes LAN+, LAN-, A, B. (LAN addressing set via DIP switches)
Siren Outputs: 1 x Internal & 1 x External variable tone Siren Outputs*
Power Supply: 1 x Integriti External Power Supply Connection
Power Outputs: 4 x 13.75Vdc nominal outputs (DET+/DET- Detector Power)
External Power Supply Monitoring (Compatible with IR SMART PSU Devices)
AC Fail: External PS AC Fail
Low Battery: External PS Low Battery
LAN Fuse: External PS LAN Fuse
Detector Fuse: External PS Detector Fuse
Low Volts: External PS Low Volts
PSU Fail: External PS Fail
Compliance
Electrical: CE
Environmental: ROHS
*Siren drivers fitted from PCB revision “B”